Controller Description
External accessories interface terminal 1-20
①External door open signal
②Safety light signal 1
③ 12V power supply
④ GND&COM
⑤Internal door open signal
⑥Safety light signal 2
⑦ GND&COM
⑧Forced door open signal
⑨ Emergency signal (open door maintenance)
⑩ Door opening stop, safety signal
⑪ GND for electronic lock
⑫ 12V power supply
⑬ GND&COM
⑭ Lock mode (electronic lock device)
⑮Auto mode (bidirectional)
⑯ Access control (one-way mode)
⑰ Partial open mode
⑱Enable maintenance mode
⑲External hand switch
⑳ Internal hand switch
Controller Interface Distribution
①External accessory interface (switch, probe, etc.)
②Safety electric eye interface (left blue and right black, connect up to two pairs)
③ 24V DC power supply
④Backup power interface
⑤ Motor power cord
⑥ Motor control line
Controller common menu
0.1 Door opening speed, the default value is 5, the larger the value, the faster the door opening speed
0.2 Door closing speed, the default value is 1, the larger the value, the faster the door closing speed
0.3 Turn on the direction, the default value is 2, 1: clockwise 2: counterclockwise
0.4 Open waiting time, the default value is 4, the larger the value, the longer the waiting time to open the door
0.5 Sensitivity of fast interval impact perception, the default value is 3, the lower the value, the more sensitive
0.6 Shock sensitivity in low speed range, the default value is 3, the lower the value, the more sensitive
0.9 The amount of current to maintain when the door is closed, the default value is 2, the smaller the value, the lower the current value
52 Manual door opening sensitivity, the default value is 3, the higher the value, the more difficult it is to manually open the door
Parameter setting process
Step 1: Click the UP or DOWN button to find the corresponding menu according to the digital display on the LED screen
Step 2: During the valid time, press the SET button for 3 seconds to enter the menu, and the LED displays the current value of the menu
! If the valid time has passed, please restart the operation from the first step
Step 3: Click and press the UP or DOWN key to modify the value of the menu
Step 4: Press and hold the SET button for 3 seconds to save the adjusted parameters
! If there is no save operation in step 4, the menu will return to the initial value after power off and on again.